# AWG 线规对照表(美国线规 American Wire Gauge
> 数据基准:铜导体,20°C 直流电阻;载流量为工程参考值(NEC 75°C 铜表 + 小线规常规参考),实际选型需按敷设方式、环境温度、绝缘等级降额。
## 一、完整对照表(AWG 4/0 ~ 30
| AWG | 直径 (mm) | 直径 (in) | 截面积 (mm²) | 铜电阻 @20°C (Ω/km) | 参考载流量 (A) |
|-----|-----------|-----------|--------------|---------------------|----------------|
| 4/0 (0000) | 11.684 | 0.4600 | 107.2 | 0.1608 | 230 |
| 3/0 (000) | 10.404 | 0.4096 | 85.0 | 0.2028 | 200 |
| 2/0 (00) | 9.266 | 0.3648 | 67.4 | 0.2556 | 175 |
| 1/0 (0) | 8.251 | 0.3249 | 53.5 | 0.3224 | 150 |
| 1 | 7.348 | 0.2893 | 42.4 | 0.4066 | 130 |
| 2 | 6.544 | 0.2576 | 33.6 | 0.5127 | 115 |
| 3 | 5.827 | 0.2294 | 26.7 | 0.6470 | 100 |
| 4 | 5.189 | 0.2043 | 21.2 | 0.8152 | 85 |
| 5 | 4.621 | 0.1819 | 16.8 | 1.028 | 70* |
| 6 | 4.115 | 0.1620 | 13.3 | 1.296 | 65 |
| 7 | 3.665 | 0.1443 | 10.5 | 1.634 | 55* |
| 8 | 3.264 | 0.1285 | 8.37 | 2.061 | 50 |
| 9 | 2.906 | 0.1144 | 6.63 | 2.599 | 42* |
| 10 | 2.588 | 0.1019 | 5.26 | 3.277 | 35 |
| 11 | 2.305 | 0.0907 | 4.17 | 4.132 | 30* |
| 12 | 2.053 | 0.0808 | 3.31 | 5.211 | 25 |
| 13 | 1.828 | 0.0720 | 2.62 | 6.571 | 22* |
| 14 | 1.628 | 0.0641 | 2.08 | 8.286 | 20 |
| 15 | 1.450 | 0.0571 | 1.65 | 10.45 | 17* |
| 16 | 1.291 | 0.0508 | 1.31 | 13.17 | 18 |
| 17 | 1.150 | 0.0453 | 1.04 | 16.61 | 13* |
| 18 | 1.024 | 0.0403 | 0.823 | 20.95 | 14 |
| 19 | 0.912 | 0.0359 | 0.653 | 26.42 | 10* |
| 20 | 0.812 | 0.0320 | 0.518 | 33.31 | 5* |
| 21 | 0.723 | 0.0285 | 0.410 | 42.00 | 4* |
| 22 | 0.644 | 0.0253 | 0.326 | 52.96 | 3* |
| 23 | 0.573 | 0.0226 | 0.258 | 66.79 | 2.5* |
| 24 | 0.511 | 0.0201 | 0.205 | 84.22 | 2* |
| 25 | 0.455 | 0.0179 | 0.162 | 106.2 | 1.7* |
| 26 | 0.405 | 0.0159 | 0.129 | 133.9 | 1.4* |
| 27 | 0.361 | 0.0142 | 0.102 | 168.9 | 1.2* |
| 28 | 0.321 | 0.0126 | 0.0810 | 212.9 | 1.0* |
| 29 | 0.286 | 0.0113 | 0.0642 | 268.5 | 0.8* |
| 30 | 0.255 | 0.0100 | 0.0509 | 338.6 | 0.6* |
`*` 为相邻偶数规格插值/常规工程参考,非标准表正式值。
## 二、中国常用 mm² ↔ AWG 速查
| mm² | 约等 AWG | 常见用途 |
|-----|----------|----------|
| 0.2 | 24 | 细信号线 |
| 0.3 | 22 | 屏蔽双绞引线 |
| 0.5 | 20 | 信号/控制线 |
| 0.75 | 18 | 控制线、灯线 |
| 1.0 | 17 | 控制回路 |
| 1.5 | 15 | 环路线圈本体、照明 |
| 2.5 | 13 | 环路线圈本体、插座回路 |
| 4 | 11 | 道闸/电机主回路 |
| 6 | 9 | 道闸电机、小功率设备 |
| 10 | 7 | 设备电源进线 |
| 16 | 5 | 配电支路 |
| 25 | 3 | 配电干路 |
| 35 | 2 | 总进线 |
| 50 | 1/0 | 总进线 |
| 70 | 2/0 | 大功率进线 |
| 95 | 3/0 | 大功率进线 |
| 120 | 4/0 | 大功率进线 |
## 三、速记口诀
- **每 3 档 AWG:截面积 ×2 或 ÷2**(如 10→7→4,截面积约 ×2 每档 3 级)
- **每 6 档 AWG:直径 ×2 或 ÷2**
- **号数越大线越细**AWG 10 ≈ 5.26 mm²,可用作心算锚点
- 电阻与截面积成反比:每 3 档 AWG,电阻约 ×2 或 ÷2
## 四、环路线圈应用备注(车检器)
1. **线圈本体绕线**:常用 1.5~2.5 mm²(AWG 15~13)多股软铜线,绝缘耐温 ≥105°C、绝缘耐压 ≥500V——切缝积水、电缆沟潮湿环境必须扛得住。
2. **引线到检测器**:推荐屏蔽双绞线 AWG 22~24(0.3~0.5 mm²),绞距要密,屏蔽层单端接地。别用太细的线(<0.5 mm²),端子压接处容易断。
3. **注意**:环路工作在几十 kHz 振荡,趋肤效应影响小,多股线即可。但引线超过 50m 时要考虑分布电容对振荡频率的影响——**线规不是唯一变量**,引线长度和绞合方式同样关键。
4. 检测器端子电流是 mA 级,线规主要看机械强度与压接可靠性,不必按载流量选。