mm2线规对照表补充载流量列(PVC明敷/XLPE空气中参考值)及降额要点
This commit is contained in:
@@ -1,23 +1,23 @@
|
||||
标称截面mm2,等效实心直径mm,Class1/2铜电阻_20C_Ohm_per_km,Class5软铜电阻_20C_Ohm_per_km,约等AWG,常见用途
|
||||
0.5,0.798,36.0,39.0,20,信号线、弱电控制线、屏蔽引线
|
||||
0.75,0.977,24.5,26.0,18,控制线、灯线、二次回路
|
||||
1.0,1.128,18.1,19.5,17,控制回路、仪器仪表引线
|
||||
1.5,1.382,12.1,13.3,15,环路线圈本体、照明支路
|
||||
2.5,1.784,7.41,7.98,13,环路线圈本体、插座回路、道闸电源
|
||||
4,2.257,4.61,4.95,11,道闸/电机主回路、空调回路
|
||||
6,2.764,3.08,3.3,9,道闸电机、小功率设备进线
|
||||
10,3.568,1.83,1.91,7,设备电源进线、充电桩支路
|
||||
16,4.514,1.15,1.21,5,配电支路、充电桩回路
|
||||
25,5.642,0.727,0.78,3,配电干路、进线
|
||||
35,6.676,0.524,0.554,2,总进线、充电桩干线
|
||||
50,7.979,0.387,0.386,1/0,总进线、母排连接
|
||||
70,9.441,0.268,0.272,2/0,大功率进线
|
||||
95,10.998,0.193,0.206,3/0,低压出线、大功率回路
|
||||
120,12.361,0.153,0.161,4/0,低压主进线
|
||||
150,13.820,0.124,0.129,—,低压主进线
|
||||
185,15.348,0.0991,0.106,—,低压主进线
|
||||
240,17.481,0.0754,0.0801,—,低压主进线、密集型母线
|
||||
300,19.544,0.0601,0.0641,—,低压主进线、母线槽
|
||||
400,22.568,0.047,0.0486,—,大截面电缆、母线
|
||||
500,25.231,0.0366,0.0384,—,大截面电缆、母线
|
||||
630,28.322,0.0287,0.0287,—,大截面电缆、母线
|
||||
标称截面mm2,等效实心直径mm,Class1/2铜电阻_20C_Ohm_per_km,Class5软铜电阻_20C_Ohm_per_km,约等AWG,常见用途,PVC载流量参考A,XLPE载流量参考A
|
||||
0.5,0.798,36.0,39.0,20,信号线、弱电控制线、屏蔽引线,10,
|
||||
0.75,0.977,24.5,26.0,18,控制线、灯线、二次回路,13,
|
||||
1.0,1.128,18.1,19.5,17,控制回路、仪器仪表引线,16,
|
||||
1.5,1.382,12.1,13.3,15,环路线圈本体、照明支路,20,24
|
||||
2.5,1.784,7.41,7.98,13,环路线圈本体、插座回路、道闸电源,27,32
|
||||
4,2.257,4.61,4.95,11,道闸/电机主回路、空调回路,36,42
|
||||
6,2.764,3.08,3.3,9,道闸电机、小功率设备进线,46,54
|
||||
10,3.568,1.83,1.91,7,设备电源进线、充电桩支路,63,57
|
||||
16,4.514,1.15,1.21,5,配电支路、充电桩回路,85,76
|
||||
25,5.642,0.727,0.78,3,配电干路、进线,112,101
|
||||
35,6.676,0.524,0.554,2,总进线、充电桩干线,138,124
|
||||
50,7.979,0.387,0.386,1/0,总进线、母排连接,168,149
|
||||
70,9.441,0.268,0.272,2/0,大功率进线,213,188
|
||||
95,10.998,0.193,0.206,3/0,低压出线、大功率回路,258,226
|
||||
120,12.361,0.153,0.161,4/0,低压主进线,299,261
|
||||
150,13.820,0.124,0.129,—,低压主进线,344,299
|
||||
185,15.348,0.0991,0.106,—,低压主进线,392,340
|
||||
240,17.481,0.0754,0.0801,—,低压主进线、密集型母线,461,400
|
||||
300,19.544,0.0601,0.0641,—,低压主进线、母线槽,530,458
|
||||
400,22.568,0.047,0.0486,—,大截面电缆、母线,620,540
|
||||
500,25.231,0.0366,0.0384,—,大截面电缆、母线,705,620
|
||||
630,28.322,0.0287,0.0287,—,大截面电缆、母线,800,720
|
||||
|
||||
|
@@ -4,32 +4,35 @@
|
||||
|
||||
> 直径列为**等效实心圆导体直径** d=2√(A/π);绞合导体实际外径约大 8%~15%,以电缆制造商样本为准。
|
||||
|
||||
> 载流量为**工程参考值**(保守口径):PVC 列=铜芯 BV 线空气中明敷、环境 30°C、单根;XLPE 列=铜芯 YJV 电缆空气中敷设、环境 40°C。实际需按敷设方式(穿管/桥架/直埋)、环境温度、并敷根数、绝缘老化等**降额**,正式设计查《工业与民用配电设计手册》或 GB/T 16895 系列。
|
||||
|
||||
> AWG 列为**截面最接近**的近似对照(中国工程选型以 mm² 为准)。
|
||||
|
||||
| 标称截面 (mm²) | 等效直径 (mm) | Class 1/2 铜电阻 @20°C (Ω/km) | Class 5 软铜电阻 @20°C (Ω/km) | 约等 AWG | 常见用途 |
|
||||
|---------------|--------------|------------------------------|------------------------------|---------|---------|
|
||||
| 0.5 | 0.798 | 36.0 | 39.0 | 20 | 信号线、弱电控制线、屏蔽引线 |
|
||||
| 0.75 | 0.977 | 24.5 | 26.0 | 18 | 控制线、灯线、二次回路 |
|
||||
| 1.0 | 1.128 | 18.1 | 19.5 | 17 | 控制回路、仪器仪表引线 |
|
||||
| 1.5 | 1.382 | 12.1 | 13.3 | 15 | 环路线圈本体、照明支路 |
|
||||
| 2.5 | 1.784 | 7.41 | 7.98 | 13 | 环路线圈本体、插座回路、道闸电源 |
|
||||
| 4 | 2.257 | 4.61 | 4.95 | 11 | 道闸/电机主回路、空调回路 |
|
||||
| 6 | 2.764 | 3.08 | 3.3 | 9 | 道闸电机、小功率设备进线 |
|
||||
| 10 | 3.568 | 1.83 | 1.91 | 7 | 设备电源进线、充电桩支路 |
|
||||
| 16 | 4.514 | 1.15 | 1.21 | 5 | 配电支路、充电桩回路 |
|
||||
| 25 | 5.642 | 0.727 | 0.78 | 3 | 配电干路、进线 |
|
||||
| 35 | 6.676 | 0.524 | 0.554 | 2 | 总进线、充电桩干线 |
|
||||
| 50 | 7.979 | 0.387 | 0.386 | 1/0 | 总进线、母排连接 |
|
||||
| 70 | 9.441 | 0.268 | 0.272 | 2/0 | 大功率进线 |
|
||||
| 95 | 10.998 | 0.193 | 0.206 | 3/0 | 低压出线、大功率回路 |
|
||||
| 120 | 12.361 | 0.153 | 0.161 | 4/0 | 低压主进线 |
|
||||
| 150 | 13.820 | 0.124 | 0.129 | — | 低压主进线 |
|
||||
| 185 | 15.348 | 0.0991 | 0.106 | — | 低压主进线 |
|
||||
| 240 | 17.481 | 0.0754 | 0.0801 | — | 低压主进线、密集型母线 |
|
||||
| 300 | 19.544 | 0.0601 | 0.0641 | — | 低压主进线、母线槽 |
|
||||
| 400 | 22.568 | 0.047 | 0.0486 | — | 大截面电缆、母线 |
|
||||
| 500 | 25.231 | 0.0366 | 0.0384 | — | 大截面电缆、母线 |
|
||||
| 630 | 28.322 | 0.0287 | 0.0287 | — | 大截面电缆、母线 |
|
||||
| 标称截面 (mm²) | 等效直径 (mm) | Class 1/2 电阻 @20°C (Ω/km) | Class 5 软铜电阻 @20°C (Ω/km) | 约等 AWG | PVC 载流量参考 (A) | XLPE 载流量参考 (A) | 常见用途 |
|
||||
|---------------|--------------|----------------------------|------------------------------|---------|-------------------|--------------------|---------|
|
||||
| 0.5 | 0.798 | 36.0 | 39.0 | 20 | 10 | — | 信号线、弱电控制线、屏蔽引线 |
|
||||
| 0.75 | 0.977 | 24.5 | 26.0 | 18 | 13 | — | 控制线、灯线、二次回路 |
|
||||
| 1.0 | 1.128 | 18.1 | 19.5 | 17 | 16 | — | 控制回路、仪器仪表引线 |
|
||||
| 1.5 | 1.382 | 12.1 | 13.3 | 15 | 20 | 24 | 环路线圈本体、照明支路 |
|
||||
| 2.5 | 1.784 | 7.41 | 7.98 | 13 | 27 | 32 | 环路线圈本体、插座回路、道闸电源 |
|
||||
| 4 | 2.257 | 4.61 | 4.95 | 11 | 36 | 42 | 道闸/电机主回路、空调回路 |
|
||||
| 6 | 2.764 | 3.08 | 3.3 | 9 | 46 | 54 | 道闸电机、小功率设备进线 |
|
||||
| 10 | 3.568 | 1.83 | 1.91 | 7 | 63 | 57 | 设备电源进线、充电桩支路 |
|
||||
| 16 | 4.514 | 1.15 | 1.21 | 5 | 85 | 76 | 配电支路、充电桩回路 |
|
||||
| 25 | 5.642 | 0.727 | 0.78 | 3 | 112 | 101 | 配电干路、进线 |
|
||||
| 35 | 6.676 | 0.524 | 0.554 | 2 | 138 | 124 | 总进线、充电桩干线 |
|
||||
| 50 | 7.979 | 0.387 | 0.386 | 1/0 | 168 | 149 | 总进线、母排连接 |
|
||||
| 70 | 9.441 | 0.268 | 0.272 | 2/0 | 213 | 188 | 大功率进线 |
|
||||
| 95 | 10.998 | 0.193 | 0.206 | 3/0 | 258 | 226 | 低压出线、大功率回路 |
|
||||
| 120 | 12.361 | 0.153 | 0.161 | 4/0 | 299 | 261 | 低压主进线 |
|
||||
| 150 | 13.820 | 0.124 | 0.129 | — | 344 | 299 | 低压主进线 |
|
||||
| 185 | 15.348 | 0.0991 | 0.106 | — | 392 | 340 | 低压主进线 |
|
||||
| 240 | 17.481 | 0.0754 | 0.0801 | — | 461 | 400 | 低压主进线、密集型母线 |
|
||||
| 300 | 19.544 | 0.0601 | 0.0641 | — | 530 | 458 | 低压主进线、母线槽 |
|
||||
| 400 | 22.568 | 0.047 | 0.0486 | — | 620 | 540 | 大截面电缆、母线 |
|
||||
| 500 | 25.231 | 0.0366 | 0.0384 | — | 705 | 620 | 大截面电缆、母线 |
|
||||
| 630 | 28.322 | 0.0287 | 0.0287 | — | 800 | 720 | 大截面电缆、母线 |
|
||||
|
||||
## 二、导体分类(GB/T 3956 / IEC 60228)
|
||||
|
||||
| 类别 | 结构 | 典型应用 |
|
||||
@@ -49,14 +52,20 @@
|
||||
- 表中 AWG 列为"截面最接近"对照,仅供进口线材/元件换算参考;国内工程选型一律以 mm² + GB/T 3956 电阻为准。
|
||||
- 速记:mm² → AWG,截面除以 2 约为 AWG 号 +3(如 10→5 mm²,AWG 7→10)。
|
||||
|
||||
## 四、环路线圈应用备注(车检器)
|
||||
## 四、载流量降额要点(现场选线必看)
|
||||
|
||||
1. **敷设方式**:空气中明敷 > 桥架 > 穿管 > 直埋。穿管多根并敷,载流量下降明显(2~4 根管约 ×0.8~0.6)。
|
||||
2. **环境温度**:PVC 基准 30°C、XLPE 基准 40°C;温度升高需乘温度校正系数(如 40°C 时 PVC 约 ×0.87)。
|
||||
3. **电压降校核**:长距离回路除载流量外必须校压降(ΔU = I×L×R),一般 ≤5%。环路引线虽电流小,但几十 kHz 下分布参数影响大于直流电阻,线规按机械强度选即可。
|
||||
|
||||
## 五、环路线圈应用备注(车检器)
|
||||
|
||||
1. **线圈本体绕线**:常用 1.5~2.5 mm² 多股软铜线(Class 5,BVR 类),绝缘耐温 ≥105°C、绝缘耐压 ≥500V——切缝积水、电缆沟潮湿环境必须扛得住。
|
||||
2. **引线到检测器**:推荐屏蔽双绞线 0.3~0.5 mm²(对应 AWG 22~24),绞距要密,屏蔽层单端接地。别用太细的线(<0.5 mm²),端子压接处容易断。
|
||||
3. **注意**:环路工作在几十 kHz 振荡,趋肤效应影响小,多股线即可。但引线超过 50m 时要考虑分布电容对振荡频率的影响——**线规不是唯一变量**,引线长度和绞合方式同样关键。
|
||||
4. 检测器端子电流是 mA 级,线规主要看机械强度与压接可靠性,不必按载流量选。
|
||||
|
||||
## 五、关联文档
|
||||
## 六、关联文档
|
||||
|
||||
- AWG 为主表的完整对照(AWG 4/0 ~ 30,含载流量):见同目录 `awg对照表.md` / `awg对照表.csv`
|
||||
- 本表数据文件:`线规对照表_mm2_GB3956.csv`
|
||||
Reference in New Issue
Block a user